Neuroradiology ; 66(4): 589-599, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38400954

RESUMO

PURPOSE: Compare extracranial internal carotid artery flow rates and intracranial collateral use between conventional ≥ 50% carotid stenosis and carotid near-occlusion, and between symptomatic and asymptomatic carotid near-occlusion. METHODS: We included patients with ≥ 50% carotid stenosis. Degree of stenosis was diagnosed on CTA. Mean blood flow rates were assessed with four-dimensional phase-contrast MRI. RESULTS: We included 110 patients of which 83% were symptomatic, and 38% had near-occlusion. Near-occlusions had lower mean internal carotid artery flow (70 ml/min) than conventional ≥ 50% stenoses (203 ml/min, P < .001). Definite use of ≥ 1 collateral was found in 83% (35/42) of near-occlusions and 10% (7/68) of conventional stenoses (P < .001). However, there were no differences in total cerebral blood flow (514 ml/min vs. 519 ml/min, P = .78) or ipsilateral hemispheric blood flow (234 vs. 227 ml/min, P = .52), between near-occlusions and conventional ≥ 50% stenoses, based on phase-contrast MRI flow rates. There were no differences in total cerebral or hemispheric blood flow, or collateral use, between symptomatic and asymptomatic near-occlusions. CONCLUSION: Near-occlusions have lower internal carotid artery flow rates and more collateral use, but similar total cerebral blood flow and hemispheric blood flow, compared to conventional ≥ 50% carotid stenosis.


Assuntos
Doenças das Artérias Carótidas , Estenose das Carótidas , Humanos , Constrição Patológica , Artéria Carótida Interna , Imageamento por Ressonância Magnética , Circulação Cerebrovascular/fisiologia
2.
Eur Stroke J ; 9(1): 135-143, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38032058

RESUMO

INTRODUCTION: The aim of this study was to assess sensitivity, specificity and interrater reliability of phase-contrast MRI (PC-MRI) for diagnosing carotid near-occlusion. PATIENTS AND METHODS: Prospective cross-sectional study conducted between 2018 and 2021. We included participants with suspected 50%-100% carotid stenosis on at least one side, all were examined with CT angiography (CTA) and PC-MRI and both ICAs were analyzed. Degree of stenosis on CTA was the reference test. PC-MRI-based blood flow rates in extracranial ICA and intracranial cerebral arteries were assessed. ICA-cerebral blood flow (CBF) ratio was defined as ICA divided by sum of both ICAs and Basilar artery. RESULTS: We included 136 participants. The ICAs were 102 < 50% stenosis, 88 conventional ⩾50% stenosis (31 with ⩾70%), 49 near-occlusion, 12 occlusions, 20 unclear cause of small distal ICA on CTA and one excluded. For separation of near-occlusion and conventional stenoses, ICA flow rate and ICA-CBF ratio had the highest area under the curve (AUC; 0.98-0.99) for near-occlusion. ICA-CBF ratio ⩽0.225 was 90% (45/49) sensitive and 99% (188/190) specific for near-occlusion. Inter-rater reliability for this threshold was excellent (kappa 0.98). Specificity was 94% (29/31) for cases with ⩾70% stenosis. PC-MRI had modest performance for separating <50% and conventional ⩾50% stenosis (highest AUC 0.74), and eight (16%) of near-occlusions were not distinguishable from occlusion (no visible flow). CONCLUSION: ICA-CBF ratio ⩽0.225 on PC-MRI is an accurate and reliable method to separate conventional ⩾50% stenosis and near-occlusion that is feasible for routine use. PC-MRI should be considered further as a potential standard method for near-occlusion detection, to be used side-by-side with established modalities as PC-MRI cannot separate other degrees of stenosis.


Assuntos
Estenose das Carótidas , Humanos , Estenose das Carótidas/diagnóstico por imagem , Constrição Patológica , Reprodutibilidade dos Testes , Estudos Prospectivos , Estudos Transversais , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética
3.
Clin Biomech (Bristol, Avon) ; 100: 105827, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36435076

RESUMO

BACKGROUND: Maintaining cerebral perfusion pressure in the brain when a carotid artery is closed during vascular surgery is critical for avoiding intraoperative hypoperfusion and risk of ischemic stroke. Here we propose and evaluate a method based on computational fluid dynamics for predicting patient-specific cerebral perfusion pressures at carotid clamping during carotid endarterectomy. METHODS: The study consisted of 22 patients with symptomatic carotid stenosis who underwent carotid endarterectomy (73 ± 5 years, 59-80 years, 17 men). The geometry of the circle of Willis was obtained preoperatively from computed tomography angiography and corresponding flow rates from four-dimensional flow magnetic resonance imaging. The patients were also classified as having a present or absent ipsilateral posterior communicating artery based on computed tomography angiography. The predicted mean stump pressures from computational fluid dynamics were compared with intraoperatively measured stump pressures from carotid endarterectomy. FINDINGS: On group level, there was no difference between the predicted and measured stump pressures (-0.5 ± 13 mmHg, P = 0.86) and the pressures were correlated (r = 0.44, P = 0.039). Omitting two outliers, the correlation increased to r = 0.78 (P < 0.001) (-1.4 ± 8.0 mmHg, P = 0.45). Patients with a present ipsilateral posterior communicating artery (n = 8) had a higher measured stump pressure than those with an absent artery (n = 12) (P < 0.001). INTERPRETATION: The stump pressure agreement indicates that the computational fluid dynamics approach was promising in predicting cerebral perfusion pressures during carotid clamping, which may prove useful in the preoperative planning of vascular interventions.


Assuntos
Circulação Cerebrovascular , Hidrodinâmica , Humanos
5.
Sci Rep ; 12(1): 10172, 2022 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-35715506

RESUMO

Visualizing medical images from patients as physical 3D models (phantom models) have many roles in the medical field, from education to preclinical preparation and clinical research. However, current phantom models are generally generic, expensive, and time-consuming to fabricate. Thus, there is a need for a cost- and time-efficient pipeline from medical imaging to patient-specific phantom models. In this work, we present a method for creating complex 3D sacrificial molds using an off-the-shelf water-soluble resin and a low-cost desktop 3D printer. This enables us to recreate parts of the cerebral arterial tree as a full-scale phantom model ([Formula: see text] cm) in transparent silicone rubber (polydimethylsiloxane, PDMS) from computed tomography angiography images (CTA). We analyzed the model with magnetic resonance imaging (MRI) and compared it with the patient data. The results show good agreement and smooth surfaces for the arteries. We also evaluate our method by looking at its capability to reproduce 1 mm channels and sharp corners. We found that round shapes are well reproduced, whereas sharp features show some divergence. Our method can fabricate a patient-specific phantom model with less than 2 h of total labor time and at a low fabrication cost.


Assuntos
Impressão Tridimensional , Água , Artérias , Encéfalo , Humanos , Imagens de Fantasmas
6.
PLoS One ; 16(1): e0245337, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33417614

RESUMO

An internal carotid artery (ICA) stenosis can potentially decrease the perfusion pressure to the brain. In this study, computational fluid dynamics (CFD) was used to study if there was a hemispheric pressure laterality between the contra- and ipsilateral middle cerebral artery (MCA) in patients with a symptomatic ICA stenosis. We further investigated if this MCA pressure laterality (ΔPMCA) was related to the hemispheric flow laterality (ΔQ) in the anterior circulation, i.e., ICA, proximal MCA and the proximal anterior cerebral artery (ACA). Twenty-eight patients (73±6 years, range 59-80 years, 21 men) with symptomatic ICA stenosis were included. Flow rates were measured using 4D flow MRI data (PC-VIPR) and vessel geometries were obtained from computed tomography angiography. The ΔPMCA was calculated from CFD, where patient-specific flow rates were applied at all input- and output boundaries. The ΔPMCA between the contra- and ipsilateral side was 6.4±8.3 mmHg (p<0.001) (median 3.9 mmHg, range -1.3 to 31.9 mmHg). There was a linear correlation between the ΔPMCA and ΔQICA (r = 0.85, p<0.001) and ΔQACA (r = 0.71, p<0.001), respectively. The correlation to ΔQMCA was weaker (r = 0.47, p = 0.011). In conclusion, the MCA pressure laterality obtained with CFD, is a promising physiological biomarker that can grade the hemodynamic disturbance in patients with a symptomatic ICA stenosis.


Assuntos
Estenose das Carótidas/fisiopatologia , Artéria Cerebral Média/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Feminino , Hemodinâmica , Humanos , Hidrodinâmica , Masculino , Pessoa de Meia-Idade
7.
J Cereb Blood Flow Metab ; 40(12): 2429-2440, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31722598

RESUMO

Recent reports have suggested that age-related arterial stiffening and excessive cerebral arterial pulsatility cause blood-brain barrier breakdown, brain atrophy and cognitive decline. This has spurred interest in developing non-invasive methods to measure pulsatility in distal vessels, closer to the cerebral microcirculation. Here, we report a method based on four-dimensional (4D) flow MRI to estimate a global composite flow waveform of distal cerebral arteries. The method is based on finding and sampling arterial waveforms from thousands of cross sections in numerous small vessels of the brain, originating from cerebral cortical arteries. We demonstrate agreement with internal and external reference methods and show the ability to capture significant increases in distal cerebral arterial pulsatility as a function of age. The proposed approach can be used to advance our understanding regarding excessive arterial pulsatility as a potential trigger of cognitive decline and dementia.


Assuntos
Encéfalo/irrigação sanguínea , Artérias Cerebrais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Fluxo Pulsátil/fisiologia , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Atrofia/diagnóstico por imagem , Barreira Hematoencefálica/patologia , Encéfalo/patologia , Artérias Cerebrais/fisiopatologia , Disfunção Cognitiva/fisiopatologia , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade
8.
J Magn Reson Imaging ; 51(5): 1516-1525, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31713964

RESUMO

BACKGROUND: Four-dimensional flow magnetic resonance imaging (4D flow MRI) enables efficient investigation of cerebral blood flow pulsatility in the cerebral arteries. This is important for exploring hemodynamic mechanisms behind vascular diseases associated with arterial pulsations. PURPOSE: To investigate the feasibility of pulsatility assessments with 4D flow MRI, its agreement with reference two-dimensional phase-contrast MRI (2D PC-MRI) measurements, and to demonstrate how 4D flow MRI can be used to assess cerebral arterial compliance and cerebrovascular resistance in major cerebral arteries. STUDY TYPE: Prospective. SUBJECTS: Thirty-five subjects (20 women, 79 ± 5 years, range 70-91 years). FIELD STRENGTH/SEQUENCE: 4D flow MRI (PC-VIPR) and 2D PC-MRI acquired with a 3T scanner. ASSESSMENT: Time-resolved flow was assessed in nine cerebral arteries. From the pulsatile flow waveform in each artery, amplitude (ΔQ), volume load (ΔV), and pulsatility index (PI) were calculated. To reduce high-frequency noise in the 4D flow MRI data, the flow waveforms were low-pass filtered. From the total cerebral blood flow, total PI (PItot ), total volume load (ΔVtot ), cerebral arterial compliance (C), and cerebrovascular resistance (R) were calculated. STATISTICAL TESTS: Two-tailed paired t-test, intraclass correlation (ICC). RESULTS: There was no difference in ΔQ between 4D flow MRI and the reference (0.00 ± 0.022 ml/s, mean ± SEM, P = 0.97, ICC = 0.95, n = 310) with a cutoff frequency of 1.9 Hz and 15 cut plane long arterial segments. For ΔV, the difference was -0.006 ± 0.003 ml (mean ± SEM, P = 0.07, ICC = 0.93, n = 310) without filtering. Total R was 11.4 ± 2.41 mmHg/(ml/s) (mean ± SD) and C was 0.021 ± 0.009 ml/mmHg (mean ± SD). ΔVtot was 1.21 ± 0.29 ml (mean ± SD) with an ICC of 0.82 compared with the reference. PItot was 1.08 ± 0.21 (mean ± SD). DATA CONCLUSION: We successfully assessed 4D flow MRI cerebral arterial pulsatility, cerebral arterial compliance, and cerebrovascular resistance. Averaging of multiple cut planes and low-pass filtering was necessary to assess accurate peak-to-peak features in the flow rate waveforms. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:1516-1525.


Assuntos
Circulação Cerebrovascular , Imageamento por Ressonância Magnética , Velocidade do Fluxo Sanguíneo , Artérias Cerebrais , Feminino , Humanos , Imageamento Tridimensional , Estudos Prospectivos , Fluxo Pulsátil
9.
J Magn Reson Imaging ; 50(2): 511-518, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30637846

RESUMO

BACKGROUND: Accelerated 4D flow MRI allows for high-resolution velocity measurements with whole-brain coverage. Such scans are increasingly used to calculate flow rates of individual arteries in the vascular tree, but detailed information about the accuracy and precision in relation to different postprocessing options is lacking. PURPOSE: To evaluate and optimize three proposed segmentation methods and determine the accuracy of in vivo 4D flow MRI blood flow rate assessments in major cerebral arteries, with high-resolution 2D PCMRI as a reference. STUDY TYPE: Prospective. SUBJECTS: Thirty-five subjects (20 women, 79 ± 5 years, range 70-91 years). FIELD STRENGTH/SEQUENCE: 4D flow MRI with PC-VIPR and 2D PCMRI acquired with a 3 T scanner. ASSESSMENT: We compared blood flow rates measured with 4D flow MRI, to the reference, in nine main cerebral arteries. Lumen segmentation in the 4D flow MRI was performed with k-means clustering using four different input datasets, and with two types of thresholding methods. The threshold was defined as a percentage of the maximum intensity value in the complex difference image. Local and global thresholding approaches were used, with evaluated thresholds from 6-26%. STATISTICAL TESTS: Paired t-test, F-test, linear correlation (P < 0.05 was considered significant) along with intraclass correlation (ICC). RESULTS: With the thresholding methods, the lowest average flow difference was obtained for 20% local (0.02 ± 15.0 ml/min, ICC = 0.97, n = 310) or 10% global (0.08 ± 17.3 ml/min, ICC = 0.97, n = 310) thresholding with a significant lower standard deviation for local (F-test, P = 0.01). For all clustering methods, we found a large systematic underestimation of flow compared with 2D PCMRI (16.1-22.3 ml/min). DATA CONCLUSION: A locally adapted threshold value gives a more stable result compared with a globally fixed threshold. 4D flow with the proposed segmentation method has the potential to become a useful reliable clinical tool for assessment of blood flow in the major cerebral arteries. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:511-518.


Assuntos
Artérias Cerebrais/fisiologia , Avaliação Geriátrica/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Cerebrais/diagnóstico por imagem , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes